wood wall sheathing splice requirements

wood wall sheathing splice requirements

Nailing Patterns -Common Nailing Schedules & Why They Are So ...

Each end and splice also needs three 12-16d; Roof and wall sheathing- 8-10d every 4-6” on the seams and 8-12” in the field; Shingles- Six roofing nails or staples per shingle. Tab shingles need two nails on each side of the tab

Get Price

IRC2015 - CHAPTER 6

The International Code Council (ICC) is a non-profit organization dedicated to developing model codes and standards used in the design build and compliance process.

Get Price

CHAPTER 5: Design of Wood Framing - HUD User

wood; therefore this chapter focuses on structural design that specifies standard dimension lumber and structural wood panels (i.e. plywood and oriented strand board sheathing). Design of the lateral force resisting system (i.e. shearwalls and diaphragms) must be approached from a system design perspective and is addressed in Chapter 6.

Get Price

LP® LongLength XL™ OSB Sheathing - LP Building Solutions

OSB Sheathing LP® LongLength XL™ panels are designed to help builders meet the lateral wind shear load and wind uplift load requirements of the IBC (Section 6.4.2.2 of ASCE-7) or IRC (R301.2.1) by providing additional panel length allowing the transfer of these loads from the upper top plate of the wood

Get Price

Simpson Connectors - Strong-Tie Wood Connectors

Sheathing clips are metal clips designed to be used in between wooden structures to provide support to the edges. Truss clips are light metal clips used to connect wooden trusses. Tie Plates and Mending Plates - Designed to join two pieces of lumber together both tie plates and mending plates accomplish this task through installation at the ...

Get Price

Exterior Wall Sheathing Plywood Sheathing OSB Sheathing for ...

When it comes to exterior wall sheathing GP's Plytanium plywood wall sheathing and Blue Ribbon OSB sheathing are leaders in the construction industry.

Get Price

Fully Sheathed Walls - APA – The Engineered Wood Association

Siding and trim attachment without needing to hit studs. Meet code requirements and simplify fastening of siding and trim to plywood or OSB. Continuously sheathing with OSB or plywood not only makes walls stronger and more resilient—these structural panels also make a solid consistent surface for attaching siding and trim that meets the requirements of the IRC.

Get Price

LP LongLength & LongLength XL OSB Sheathing | LP Building ...

LP ® LongLength ™ and LongLength XL ™ OSB Sheathing panels are engineered to make building for tall wall applications easier. LP LongLength sheathing can lower building costs increase wall strength and help meet code requirements in high wind and seismic zones.

Get Price

Simplified Wall Bracing - APA – The Engineered Wood Association

To view a complete list download System Report: APA Simplified Wall Bracing Method Using Wood Structural Panel Continuous Sheathing Form SR-102 shown in the right column. Basic wind speed must be 90 mph or less and the Wind Exposure Category must be A or B.

Get Price

ZIP System Wall Sheathing - Huber Engineered Woods

Document Share Contractor Checklist for ZIP System Sheathing. This checklist outlines the important observations and practices to perform successfully when installing ZIP System sheathing and R-sheathing.

Get Price

BUILDING FRAMING SYSTEMS AND BEST PRACTICES ... - FEMA.gov

sheathing (typically plywood or OSB). The IRC and IBC provide prescriptive framed shear wall designs that may be incorporated into the building design to resist lateral loads. The prescriptive designs specify requirements for wall bracing braced wall lines and braced wall panels. Nearly all homes have exterior shear walls.

Get Price

Advanced Wall Framing - Energy Star

into wall studs • Use full foam sheathing over other ap-proved wall bracing (e.g. metal strap-ping let-in wood 1x ’ s). Specific requirements for these and other methods depend on wind and seismic zone as well as the number of stories in the structure. The structural implications of sheathing make it a critical wall system component ...

Get Price

WOOD FRAME PRESCRIPTIVE PROVISIONS ONE STORY RESIDENTIAL ...

4. Exterior walls bearing walls and braced wall panels require continuous footings. R403.1 5. 23/32" plywood required for 24" joist spacing. 6. Where interior walls are shear walls wall framing and sheathing shall extend to the roof sheathing. 7. Footings on or adjacent to slopes shall meet the requirements of Section R403.1.7. 8.

Get Price

Single Family Residential Construction Guide - Wall Framing

Such walls having a stud height exceeding 14 inches (356 mm) shall be considered to be first-story walls for the purpose of determining the bracing required by Section 2326.11.3. Solid blocking or wood structural panel sheathing may be used to brace cripple walls having a stud height of 14 inches (356 mm) or less.

Get Price

Deflection of Wood Diaphragms - Washington State University

Deflection of Light Frame Wood Diaphragms Curtis Earl Abstract This paper takes an in-depth parametric look at the deflection of wood diaphragms to better understand the diaphragm deflection equation and how it is utilized. This work is intended to assist engineering judgment when calculating mid-span diaphragm deflections in wood structures.

Get Price

Single Family Residential Construction Guide - Nailing Schedule

For nailing of wood structural panel and particleboard diaphragms and shear walls refer to Section 2314.3. Nails for wall sheathing may be common box or casing. 3. Common or deformed shank. 4. Common. 5. Deformed shank. 6. Corrosion-resistant siding and casing nails conforming to the requirements of Section 2325.1. 7. Fasteners spaced 3 ...

Get Price

Minimum Residential Wood Construction Specifications

2. Wood Supported by Exterior Foundation Walls. Wood framing members including wood sheathing that rest on exterior foundation walls and are less than 8 inches (203 mm) from exposed earth shall be of naturally durable or preservative-treated wood. [CRC R317] 3. Concrete Slabs. Slabs on grade must be at least 3 ½” thick. [CBC Section 1907]

Get Price

CHAPTER 6 WALL CONSTRUCTION - eCodes

wall sheathing shall be fastened directly to structural framing members. Exterior wall coverings shall be capable of resisting the wind pressures listed in Table R301.2(2).Wood structural panel sheathing used for exterior walls shall conform to the requirements of Table R602.3(3). Studs shall be continuous from support at the sole plate to a

Get Price

Mid-rise Shear Walls & Diaphragms - Wood Products Council

Review shear wall code requirements. ... For wood structural panel shear walls with aspect ratios (h/b) greater than 2:1 the nominal shear ... Sheathing splice plate ...

Get Price

Product Details

Product List